Schneider Electric - HMISCU8B5 5”7 colour touch controller panel
£780.00
£650.00
Range of Product | Harmony SCU |
---|---|
Product or Component Type | Small touch HMI controller |
Display size | 5.7 inch |
Display type | Backlit LED colour TFT LCD |
Touch panel | Analogue |
Device presentation | Complete product |
Display Resolution | 320 x 240 pixels QVGA |
---|---|
Backlight lifespan | 50000 hours 65000 colours |
Brightness | 16 levels via touch panel |
View angle horiz x vert | 60° left 60° right 40° top 60° bottom |
character font | Chinese (simplified Chinese) Japanese (ANK, Kanji) ASCII Korean Taiwanese (traditional Chinese) |
supply | External source |
[Us] rated supply voltage | 24 V 20.4…28.8 V)DC |
Immunity to microbreaks | 10 ms |
Inrush current | 30 A |
Power Consumption in W | 24 W |
Local signalling | No indicator |
Number of pages | Limited by internal memory capacity |
Software Designation | SoMachine |
Operating System | Harmony |
Processor name | CPU RISC |
Processor frequency | 333 MHz |
Memory description | Flash NAND, 128 MB Internal data storage FRAM, 128 kB Application run DRAM, 128 MB |
Integrated connection type | 1 serial link - RJ45 - RS232/RS485 <= 115.2 kbits/s) 1 Ethernet TCP/IP - RJ45 1 USB 2.0 type mini B 1 USB 2.0 type A CANopen master bus - SUB-D 9 |
Realtime clock | Built-in |
Downloadable protocols | Modbus Modbus TCP/IP CANopen |
Fixing mode | By 1 nut Ø 22 mm 1...6 mm thick panel |
Enclosure Material | PC/PBT and PAA |
Shock resistance | 147 m/s² 11 ms on DIN rail)IEC 60068-2-27 294 m/s² 6 ms on panel mounting)IEC 60068-2-27 |
Vibration resistance | +/- 3.5 mm 5…9 Hz) IEC 60068-2-6 1 gn 9…150 Hz) IEC 60068-2-6 |
Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4 Surge immunity test - test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5 Surge immunity test - test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5 Surge immunity test - test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5 Surge immunity test - test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011 Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011 |
Discrete input number | 2 fast input (normal mode) IEC 61131-2 Type 1 6 digital input IEC 61131-2 Type 1 |
Discrete input voltage | 24 V DC sink or source (positive/negative) |
Number of common point | 1 fast input (HSC mode) 1 digital input |
Discrete input current | 7.83 mA fast input 5 mA digital |
Input impedance | 4.7 kOhm 2.81 kOhm |
Sensor power supply | 15…28.8 V DC >= 15 V >= 5 mA <= 5 V <= 1.5 mA 15…28.8 V DC >= 15 V >= 2.5 mA <= 5 V <= 1 mA |
Configurable filtering time | 0 ms no filter none) 0.004...0.04 ms bounce filter latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 3...12 ms integrator none/run/stop) |
Maximum input frequency | 100 kHz fast input (encoder mode) A/B 100 kHz fast input single phase 100 kHz fast input pulse/direction |
Maximum cable distance between devices | Shielded cable <32.81 ft (10 m) fast input Shielded cable <328.08 ft (100 m) digital input Unshielded cable <164.04 ft (50 m) digital input |
Connection pitch | 0.14 in (3.5 mm) |
Overvoltage protection | With |
Isolation between channels and internal logic | 500 V DC |
Isolation between channels | None |
Discrete output number | 2 fast output (normal mode) source 6 digital output source |
Discrete output voltage | 24 V DC 19.2...28.8 V)transistor 24 V DC 5...30 V)relay 220 V AC 100...250 V)relay |
Input/output number | 2 fast input FI0...FI1 2 fast output FQ0...FQ1 6 digital input DI0...DI5 6 digital output DQ0...DQ5 |
Discrete output current | 2 A 4 A)5 ms opening contact digital output 2 A 4 A)2 ms closing contact digital output 300 mA2 ms fast output (normal mode) 50 mA2 ms fast output (PWM or PTO mode) |
Insulation resistance | > 10 MOhm between the I/O and internal logic > 10 MOhm between power supply and earth |
Maximum output frequency | 100 kHz fast output (PTO mode) 1 kHz fast output (PWM mode) |
Absolute accuracy error | +/- 0.1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) 1 % of full scale cyclic ratio 1...99% fast output (PWM or PTO mode) +/- 5 % of full scale cyclic ratio 10...90% fast output (PWM or PTO mode) +/- 10 % of full scale cyclic ratio 20...80% fast output (PWM or PTO mode) +/- 15 % of full scale cyclic ratio 30...70% fast output (PWM or PTO mode) |
Analogue input number | 2 analog input 2 RTDs |
Analogue input range | 0...20 mA/4...20 mA 12 bits 250 Ohm +/- 1 %) -10...+10 V or 0...10 V 12 bits + sign >= 1 MOhm |
Analogue input type | RTD - 200...600 °C 16 bitsPt 100/Pt 1000 RTD - 50...200 °C 16 bitsNi 100/Ni 1000 RTD - 200...760 °C 16 bits thermocouple J) RTD - 240...1370 °C 16 bits thermocouple K) RTD 0...1600 °C 16 bits thermocouple R) RTD 200...1800 °C 16 bits thermocouple B) RTD 0...1600 °C 16 bits thermocouple S) RTD - 200...400 °C 16 bits thermocouple T) RTD - 200...900 °C 16 bits thermocouple E) RTD - 200...1300 °C 16 bits thermocouple N) |
Analogue output number | 2 resistive load 12 bits + sign |
Analogue output range | 0...20 mA/4...20 mA > 300 Ohm)open-circuit -10...10 V/0...10 V > 2 kOhm)short-circuit |
Height | 5.09 in (129.4 mm) |
Width | 6.42 in (163 mm) |
Depth | 3.00 in (76.22 mm) |
Net Weight | 1.77 lb(US) (0.803 kg) |
standards | FCC Class A EN 61131-2 UL 508 IEC 61000-6-2 CSA C22.2 No 213 Class I Division 2 ANSI/ISA 12-12-01 |
---|---|
Product Certifications | cULus 508 cULus CSA 22-2 No 142 GOST cUL 1604 Class 1 Division 2 C-tick KCC UKCA UKEX |
Marking | CE |
Ambient air temperature for operation | 32…122 °F (0…50 °C) |
Ambient Air Temperature for Storage | -4…140 °F (-20…60 °C) |
Relative humidity | 5…85 % without condensation |
Operating altitude | <= 6561.68 ft (2000 m) |
Storage altitude | 0.00…32808.40 ft (0…10000 m) |
Maximum pressure | 800...1114 hPa |
IP degree of protection | IP20 IEC 60529 rear panel) IP65 IEC 60529 front panel) |
NEMA degree of protection | NEMA 4X front panel |
Pollution degree | 2 IEC 60664 |
Environmental characteristic | Corrosive gas free |
Category | 22568-HMI CONTROLLERS |
---|---|
Discount Schedule | MC2 |
GTIN | 3595864175584 |
Returnability | Yes |
Country of origin | CN |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 7.40 in (18.8 cm) |
Package 1 Width | 4.33 in (11 cm) |
Package 1 Length | 8.15 in (20.7 cm) |
Package 1 Weight | 3.01 lb(US) (1.364 kg) |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 4 |
Package 2 Height | 11.81 in (30 cm) |
Package 2 Width | 11.81 in (30 cm) |
Package 2 Length | 15.75 in (40 cm) |
Package 2 Weight | 13.15 lb(US) (5.964 kg) |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 64 |
Package 3 Height | 29.53 in (75 cm) |
Package 3 Width | 31.50 in (80 cm) |
Package 3 Length | 47.24 in (120 cm) |
Package 3 Weight | 299.34 lb(US) (135.776 kg) |